| Date, Time |
Time_ms |
StateAfter |
MsgNumber |
MsgText |
| 04.06.2018, 16:10 |
43255673650,8102 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 04.06.2018, 16:10 |
43255673650,8102 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 04.06.2018, 16:11 |
43255674414,2824 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 04.06.2018, 16:12 |
43255675246,5394 |
0 (STOP) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 04.06.2018, 16:12 |
43255675246,5394 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 04.06.2018, 16:12 |
43255675246,5394 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 05.06.2018, 20:08 |
43256839072,5579 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 05.06.2018, 21:44 |
43256906045,2662 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 06.06.2018, 09:53 |
43257412179,4676 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 06.06.2018, 09:53 |
43257412272,0718 |
0 (STOP) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 06.06.2018, 11:07 |
43257463829,6065 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 06.06.2018, 11:08 |
43257463899,0625 |
0 (STOP) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 09.06.2018, 03:50 |
43260159825,1968 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 09.06.2018, 03:50 |
43260159825,1968 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 09.06.2018, 03:50 |
43260159825,1968 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1100 |
Main power supply interrupted (U = 405.4 V) |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 09.06.2018, 03:50 |
43260159836,7593 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 09.06.2018, 03:50 |
43260159883,0787 |
0 (STOP) |
1092 |
Condenser 2 is not ready |
| 09.06.2018, 03:50 |
43260159883,0787 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 09.06.2018, 03:52 |
43260161213,1134 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 09.06.2018, 03:52 |
43260161213,1134 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 09.06.2018, 04:51 |
43260202570,5903 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 09.06.2018, 04:51 |
43260202570,5903 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 09.06.2018, 04:56 |
43260206143,2407 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 09.06.2018, 04:56 |
43260206143,2407 |
0 (STOP) |
1108 |
Compressor block 2 - phase monitor alarm |
| 09.06.2018, 04:56 |
43260206212,6968 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 09.06.2018, 04:56 |
43260206212,6968 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 09.06.2018, 10:45 |
43260448034,2014 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 09.06.2018, 10:45 |
43260448103,6806 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 09.06.2018, 10:45 |
43260448103,6806 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 09.06.2018, 10:45 |
43260448115,2431 |
1 (START) |
1114 |
Compressor block 3 - oil low level alarm |
| 09.06.2018, 10:49 |
43260450879,8611 |
0 (STOP) |
1114 |
Compressor block 3 - oil low level alarm |
| 09.06.2018, 10:57 |
43260456618,3681 |
1 (START) |
1140 |
Compressor block 3 - Compressor 1 low oil flow alarm |
| 09.06.2018, 10:57 |
43260456838,3102 |
0 (STOP) |
1140 |
Compressor block 3 - Compressor 1 low oil flow alarm |
| 11.06.2018, 10:12 |
43262425476,7708 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 11.06.2018, 10:30 |
43262437760,2083 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 11.06.2018, 11:15 |
43262469408,2523 |
1 (START) |
1125 |
Compressor block 1 - Compressor 2 low oil flow alarm |
| 11.06.2018, 11:16 |
43262469685,3588 |
0 (STOP) |
1125 |
Compressor block 1 - Compressor 2 low oil flow alarm |
| 11.06.2018, 13:03 |
43262543965,7407 |
1 (START) |
1128 |
Compressor block 1 - Compressor 3 low oil flow alarm |
| 11.06.2018, 13:03 |
43262544197,2569 |
0 (STOP) |
1128 |
Compressor block 1 - Compressor 3 low oil flow alarm |
| 11.06.2018, 13:37 |
43262567509,0741 |
1 (START) |
1117 |
Compressor block 1 - oil filter alarm |
| 11.06.2018, 13:37 |
43262567543,5764 |
0 (STOP) |
1117 |
Compressor block 1 - oil filter alarm |
| 11.06.2018, 14:16 |
43262594956,4236 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 11.06.2018, 14:16 |
43262594956,4236 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 11.06.2018, 14:18 |
43262595870,3125 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 11.06.2018, 14:18 |
43262595870,3125 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 11.06.2018, 14:27 |
43262602751,8866 |
1 (START) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 11.06.2018, 15:10 |
43262632185,2083 |
0 (STOP) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 11.06.2018, 16:21 |
43262681872,5695 |
1 (START) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 11.06.2018, 16:33 |
43262690012,0023 |
0 (STOP) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 12.06.2018, 08:46 |
43263365933,2639 |
1 (START) |
1137 |
Compressor block 2 - Compressor 3 low oil flow alarm |
| 12.06.2018, 08:48 |
43263366754,4792 |
0 (STOP) |
1137 |
Compressor block 2 - Compressor 3 low oil flow alarm |
| 12.06.2018, 10:11 |
43263424521,6088 |
1 (START) |
1134 |
Compressor block 2 - Compressor 2 low oil flow alarm |
| 12.06.2018, 10:11 |
43263424533,2292 |
0 (STOP) |
1134 |
Compressor block 2 - Compressor 2 low oil flow alarm |
| 12.06.2018, 10:52 |
43263453275,5324 |
1 (START) |
1131 |
Compressor block 2 - Compressor 1 low oil flow alarm |
| 12.06.2018, 10:54 |
43263454246,8634 |
0 (STOP) |
1131 |
Compressor block 2 - Compressor 1 low oil flow alarm |
| 12.06.2018, 12:23 |
43263516102,1065 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 12.06.2018, 12:37 |
43263526015,0463 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 12.06.2018, 12:56 |
43263539210,625 |
1 (START) |
1124 |
Compressor block 1 - Compressor 2 motor failure |
| 12.06.2018, 12:58 |
43263540331,088 |
0 (STOP) |
1124 |
Compressor block 1 - Compressor 2 motor failure |
| 12.06.2018, 12:58 |
43263540365,7986 |
1 (START) |
1124 |
Compressor block 1 - Compressor 2 motor failure |
| 12.06.2018, 12:58 |
43263540435,2778 |
0 (STOP) |
1124 |
Compressor block 1 - Compressor 2 motor failure |
| 12.06.2018, 13:06 |
43263546115,6482 |
1 (START) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 12.06.2018, 13:07 |
43263547006,6782 |
0 (STOP) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 12.06.2018, 13:25 |
43263559033,831 |
1 (START) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 12.06.2018, 13:30 |
43263562653,4375 |
0 (STOP) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 12.06.2018, 13:36 |
43263567025,5671 |
1 (START) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 12.06.2018, 13:41 |
43263570574,4329 |
0 (STOP) |
1121 |
Compressor block 1 - Compressor 1 motor failure |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 12.06.2018, 23:09 |
43263964750,6366 |
1 (START) |
1100 |
Main power supply interrupted (U = 403.6 V) |
| 12.06.2018, 23:09 |
43263964808,507 |
0 (STOP) |
1092 |
Condenser 2 is not ready |
| 12.06.2018, 23:09 |
43263964808,507 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 12.06.2018, 23:09 |
43263965190,5093 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 12.06.2018, 23:09 |
43263965190,5093 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 00:30 |
43264021381,7824 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 00:30 |
43264021381,7824 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 00:31 |
43264021532,1991 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 00:31 |
43264021532,1991 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 00:31 |
43264021659,5023 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 00:31 |
43264021659,5023 |
0 (STOP) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 00:42 |
43264029163,287 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 00:42 |
43264029174,8843 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 01:04 |
43264045098,3449 |
1 (START) |
1100 |
Main power supply interrupted (U = 397.1 V) |
| 13.06.2018, 01:17 |
43264053823,5185 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 01:17 |
43264053835,1273 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 01:17 |
43264053858,2407 |
1 (START) |
1124 |
Compressor block 1 - Compressor 2 motor failure |
| 13.06.2018, 01:17 |
43264053869,8264 |
0 (STOP) |
1124 |
Compressor block 1 - Compressor 2 motor failure |
| 13.06.2018, 01:17 |
43264053892,9745 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 01:17 |
43264053904,5718 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 01:17 |
43264053916,1343 |
1 (START) |
1142 |
Compressor block 3 - Compressor 2 motor failure |
| 13.06.2018, 01:17 |
43264053927,6968 |
0 (STOP) |
1142 |
Compressor block 3 - Compressor 2 motor failure |
| 13.06.2018, 01:22 |
43264057214,2708 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 01:22 |
43264057225,8796 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 01:52 |
43264078411,412 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 01:52 |
43264078422,9745 |
1 (START) |
1100 |
Main power supply interrupted (U = 398.8 V) |
| 13.06.2018, 02:29 |
43264103915,2199 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 02:29 |
43264103915,2199 |
0 (STOP) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 02:29 |
43264103949,919 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 02:29 |
43264103949,919 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 02:36 |
43264108358,6227 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 02:36 |
43264108439,6412 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 02:36 |
43264108439,6412 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 02:36 |
43264108462,7894 |
1 (START) |
1139 |
Compressor block 3 - Compressor 1 motor failure |
| 13.06.2018, 02:36 |
43264108462,7894 |
1 (START) |
1142 |
Compressor block 3 - Compressor 2 motor failure |
| 13.06.2018, 02:40 |
43264111192,3727 |
0 (STOP) |
1142 |
Compressor block 3 - Compressor 2 motor failure |
| 13.06.2018, 02:40 |
43264111250,2546 |
0 (STOP) |
1139 |
Compressor block 3 - Compressor 1 motor failure |
| 13.06.2018, 02:44 |
43264114395,4514 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 02:44 |
43264114395,4514 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 03:00 |
43264125173,6921 |
1 (START) |
1100 |
Main power supply interrupted (U = 402.8 V) |
| 13.06.2018, 03:06 |
43264129461,8171 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 03:06 |
43264129461,8171 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 03:06 |
43264129646,9676 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:06 |
43264129670,1273 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:06 |
43264129670,1273 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 03:16 |
43264136310,2083 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 03:16 |
43264136321,7824 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 03:16 |
43264136321,7824 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 03:16 |
43264136321,7824 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 03:16 |
43264136321,7824 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:16 |
43264136321,7824 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 03:16 |
43264136321,7824 |
1 (START) |
1100 |
Main power supply interrupted (U = 0 V) |
| 13.06.2018, 03:20 |
43264139287,9167 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 03:20 |
43264139287,9167 |
0 (STOP) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 03:20 |
43264139311,0764 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 03:20 |
43264139311,0764 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 03:20 |
43264139484,7106 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:20 |
43264139519,4329 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:20 |
43264139519,4329 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 03:27 |
43264143776,713 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 03:27 |
43264143776,713 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 03:38 |
43264151633,3681 |
1 (START) |
1100 |
Main power supply interrupted (U = 392.4 V) |
| 13.06.2018, 03:44 |
43264155651,8056 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:44 |
43264155698,1019 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:44 |
43264155698,1019 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 03:51 |
43264160961,794 |
1 (START) |
1100 |
Main power supply interrupted (U = 0 V) |
| 13.06.2018, 03:56 |
43264164231,1574 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 03:56 |
43264164242,7431 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 03:56 |
43264164242,7431 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 04:00 |
43264166936,088 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 04:00 |
43264166936,088 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 04:13 |
43264175708,5764 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 04:13 |
43264175719,4445 |
1 (START) |
1100 |
Main power supply interrupted (U = 0 V) |
| 13.06.2018, 04:15 |
43264177760,7292 |
0 (STOP) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 04:16 |
43264177922,7894 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 04:16 |
43264177922,7894 |
0 (STOP) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 04:16 |
43264177945,9722 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 04:16 |
43264177945,9722 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 04:16 |
43264178119,5718 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 04:16 |
43264178198,8889 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 04:16 |
43264178198,8889 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 04:23 |
43264182665,162 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 04:23 |
43264182665,162 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 04:45 |
43264198495,4167 |
1 (START) |
1100 |
Main power supply interrupted (U = 402.5 V) |
| 13.06.2018, 09:31 |
43264396546,2037 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 09:31 |
43264396569,3518 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 09:31 |
43264396569,3518 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 09:31 |
43264396824,0278 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 09:31 |
43264396972,7199 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 09:31 |
43264396972,7199 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 09:31 |
43264396984,1667 |
1 (START) |
1114 |
Compressor block 3 - oil low level alarm |
| 13.06.2018, 09:34 |
43264398765,4977 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 09:34 |
43264398765,4977 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 09:39 |
43264402583,0671 |
0 (STOP) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 09:39 |
43264402710,3935 |
0 (STOP) |
1114 |
Compressor block 3 - oil low level alarm |
| 13.06.2018, 09:39 |
43264402733,5532 |
1 (START) |
1139 |
Compressor block 3 - Compressor 1 motor failure |
| 13.06.2018, 09:40 |
43264403230,4051 |
0 (STOP) |
1139 |
Compressor block 3 - Compressor 1 motor failure |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 09:51 |
43264410980,3588 |
1 (START) |
1100 |
Main power supply interrupted (U = 388.9 V) |
| 13.06.2018, 14:29 |
43264603812,5463 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 14:29 |
43264603812,5463 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 14:31 |
43264605396,8866 |
0 (STOP) |
1114 |
Compressor block 3 - oil low level alarm |
| 13.06.2018, 14:32 |
43264605894,6412 |
1 (START) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 14:32 |
43264605940,9375 |
1 (START) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 14:32 |
43264606102,1296 |
1 (START) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 14:35 |
43264608115,1042 |
1 (START) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1010 |
0.01 - Evaporator - electrical power is switched off |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1030 |
0.03 - Evaporator - electrical power is switched off |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1020 |
0.02 - Evaporator - electrical power is switched off |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1040 |
0.04 - Evaporator - electrical power is switched off |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1050 |
0.05 - Evaporator - electrical power is switched off |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1070 |
0.07 - Evaporator - electrical power is switched off |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1091 |
Condenser 1 is not ready |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1092 |
Condenser 2 is not ready |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 14:36 |
43264608993,4028 |
1 (START) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 14:36 |
43264609005,0926 |
1 (START) |
1100 |
Main power supply interrupted (U = 403.1 V) |
| 13.06.2018, 15:17 |
43264637405,4514 |
0 (STOP) |
1082 |
Compressor block 2 is not ready |
| 13.06.2018, 15:17 |
43264637405,4514 |
0 (STOP) |
1108 |
Compressor block 2 - phase monitor alarm |
| 13.06.2018, 15:17 |
43264637428,6111 |
0 (STOP) |
1081 |
Compressor block 1 is not ready |
| 13.06.2018, 15:17 |
43264637428,6111 |
0 (STOP) |
1107 |
Compressor block 1 - phase monitor alarm |
| 13.06.2018, 15:18 |
43264637579,2477 |
0 (STOP) |
1093 |
Condenser 3 is not ready |
| 13.06.2018, 15:18 |
43264637602,2454 |
0 (STOP) |
1083 |
Compressor block 3 is not ready |
| 13.06.2018, 15:18 |
43264637602,2454 |
0 (STOP) |
1109 |
Compressor block 3 - phase monitor alarm |
| 13.06.2018, 15:25 |
43264642389,6991 |
0 (STOP) |
1110 |
Compressor block 4 - phase monitor alarm |
| 13.06.2018, 15:25 |
43264642435,9838 |
0 (STOP) |
1084 |
Compressor block 4 is not ready |
| 13.06.2018, 15:25 |
43264642459,1551 |
1 (START) |
1145 |
Compressor block 4 - Compressor 1 motor failure |
| 13.06.2018, 15:25 |
43264642470,7292 |
0 (STOP) |
1145 |
Compressor block 4 - Compressor 1 motor failure |